Power Industry & Industrial Processing

Tuxpan II – 495 MW Combined Cycle Power Plant

Fast Facts [Download Fact Sheet]

Owner
Electricidad Aguila de Altamira S. de R.L. de C.V.
Engineer
Mitsubishi Heavy Industries, Nagasaki, Japan
Application
High Pressure Boiler Feed Water Production
Equipment
Media Filtration, Two-Stage Reverse Osmosis (SWRO/BWRO), Mixed Bed Demineralization, and Decarbonator
Start Up Date
December 2001
Tuxpan II
Operating Data
Feedwater TDS: 35,000 mg/L
Reverse Osmosis Permeate: < 250 mg/L TDS
Demineralized Water: 16 Ω-cm
Scope of Work
Designed Facility, Supplied Materials, Supervised Installation and Startup

 

power-industry - power-project - tuxpan-2 -